Water reuse in industry is no longer solely an environmental activity. In plant practice, it has simultaneously become a cost, operational, and strategic issue. With increasing pressure on water resources and greater production sensitivity to supply interruptions, not only the amount of water drawn, but also the plant's ability to return, treat, and reuse it in appropriate quality, is becoming increasingly important.
From a technical point of view, however, it is not just about the reuse of wastewater itself. It is about redesigning the plant's water balance in such a way that water after one process stage becomes a medium for the next stage or returns to the same process after appropriate treatment. This is what distinguishes actual circuit closing from simple loss reduction. The plants that win are those that do not implement a single technology, but build the architecture of the entire circuit.
How to measure?
The most useful indicator is not a general declaration that the plant has reuse. The basis for assessment should be the annual volume of water that has been recovered or that no longer needs to be drawn from the primary source. In industrial practice, therefore, the best main indicator remains the value expressed in cubic meters per year. Complementary indicators should include the share of reuse in total consumption, specific water consumption per unit of production, and avoided wastewater discharge.
Most important Key Performance Indicators (KPI) for an industrial plant
| KPI | Jednostka | What does it measure? | How to interpret? |
|---|---|---|---|
| Water recovered and reused | m³/year | volume of water returned to the process or utility | shows the actual effect of reuse technology |
| Fresh water intake avoided | m³/year | how much water did not need to be drawn from the source thanks to reuse | best KPI for management and environmental balance |
| Wastewater discharge avoided | m³/year | how much wastewater did not leave the plant thanks to recirculation | shows the degree of circuit closure |
| Reuse share | % | share of recirculated water in total consumption | allows comparison of facilities of different scales |
What technologies truly close circuits?
There is no single technology good for every plant. The choice of solution depends on stream quality, salinity, organic load, process requirements, tolerance to scaling and corrosion, and whether the plant wants to reduce intake, reduce discharge, or achieve both goals simultaneously. Despite this, several groups of solutions can be identified that most often truly close water circuits.
Main technologies for closing process circuits
| Technologia | Where does it work best? | Main effect |
|---|---|---|
| Stream segregation and cascading use | rinsing, washing, processes with different water quality requirements | rapid reduction of intake without full plant reconstruction |
| Condensate recovery | steam systems, boiler rooms, textiles, food industry, chemistry | simultaneous water and energy savings |
| Treatment of „blowdown” from cooling towers | cooling systems and chilled water circuits | reduction of make-up water and stabilization of utility water |
| Membrane systems: membrane bioreactor, ultrafiltration, reverse osmosis (Reverse Osmosis, RO) | process wastewater with organic load, food industry, chemistry, light industry | production of technical water for reuse |
| Water recovered from an external source | large chemical plants, petrochemicals, energy-intensive industry | rapid substitution of fresh water intake in utility |
| Zero Liquid Discharge (ZLD), i.e., a zero-discharge system | highly saline wastewater, plants with strict discharge limits | maximum water recovery and elimination of liquid discharge |
The structure of this table corresponds to the logic of the hierarchy of actions used in industrial practice. First, actions with the lowest unit cost of recovery are utilized, and only then are membrane and zero-discharge solutions introduced.
Which technologies today yield the best documented results?
The most reliable are those implementations where the annual volume of recovered water or avoided fresh water intake is provided.
In this context, four areas currently remain best documented: condensate recovery, reuse of external water in utility, blowdown recovery from cooling towers, and Zero Liquid Discharge (ZLD) systems. It is precisely there that technology can most easily be translated into a clear effect in cubic meters per year.
How to read KPIs so as not to be misled?
The result in m³/year alone is not enough. The same value can mean a very good project in a medium-sized plant or only a partial improvement in a facility with very high water consumption. Therefore, the annual KPI should always be read together with the system scope. It is necessary to determine whether the number refers to one line, utility area, a selected cooling circuit, or the entire plant. It is also necessary to check whether it refers to actual process reuse or only to the substitution of recovered water into an auxiliary system.
Questions for interpreting the result
| Pytanie | Why is it important? | What does it verify? |
|---|---|---|
| Does the KPI refer to recovered water or avoided fresh water intake? | these indicators are not always equal | real balance effect |
| Does the water return to the process or only to utility? | process reuse usually has greater value | technological quality of implementation |
| Does wastewater discharge also decrease? | without this, the circuit may only be partially closed | degree of circuit closure |
| Is the quality of the recovered water fit-for-purpose? | not all recovered water is suitable for every application | real usefulness of technology |
How to choose technology for the type of plant?
In industrial practice, priority should be given not to the most advanced technologies, but to those that operate on the largest streams and offer the lowest cost of recovering one cubic meter per year. If a plant has a large steam system, condensate is usually analyzed first. If the main water consumption is cooling, usually the greatest potential lies in blowdown recovery and improving concentration cycles. If the limitation is wastewater with a high organic load, membrane systems become the natural path. If the dominant problem is discharge and salinity, Zero Liquid Discharge (ZLD) appears at the end of the hierarchy.
This means that a correct investment decision starts with a water balance, not a supplier's catalog. First, it is necessary to determine where the most water flows and where the cost of a lost cubic meter is highest. Only then is the technology selected. This is why two plants in the same industry may require a completely different path to achieve a similar KPI.
Water reuse in industry is not a single technology, but an architecture of the plant's water circulation. The greatest effect in cubic meters per year is usually achieved by solutions that operate on the largest streams: steam, cooling, utility water, and high-volume process wastewater.
The most reliable indicator remains avoided fresh water intake, supplemented by avoided wastewater discharge and the share of reuse in the plant's total balance. Only such a set shows whether the plant is truly closing the loop or merely improving water management in specific areas.
Don't just like, act!
Źródła
- UN-Water, Water Scarcity.
- UN-Water, Water, Food and Energy.
- European Commission, Water Reuse.
- Global Reporting Initiative, GRI 303: Water and Effluents 2018.
- United States Environmental Protection Agency, 2012 Guidelines for Water Reuse.
- CONCAWE, Definitions and Guidelines of Water Reuse, Recycling and Reclamation.
- Dow, Industrial Water Reuse: Case Study.
- AquaSPICE, Case study at Dow Terneuzen, Part I: Cooling tower blowdown treatment.
- LIFE Programme, Zero liquid discharge water reuse with added value co-products recovery in the beverage industry.
- World Bank / PaCT, Conservation of Water and Heat – Viyellatex Ltd.