Micropollutants are chemical compounds present in water and wastewater in very low concentrations, usually at the microgram or nanogram per liter level. The problem is that even such small amounts can have environmental significance if the substances are persistent, biologically active, or constantly flow into recipients.
This group includes, among others, drug residues, hormones, plant protection products, cosmetic ingredients, surfactants, corrosion inhibitors, industrial substances, per- and polyfluoroalkyl substances, and transformation products formed during treatment.
A classical municipal wastewater treatment plant was not specifically designed for their removal. Therefore, the so-called fourth treatment stage, an additional step aimed at reducing micropollutants, is becoming increasingly important.
Which micropollutant removal technologies are mature?
The most mature technologies for removing micropollutants from municipal wastewater are ozonation and activated carbon adsorption. In practice, ozone, powdered activated carbon, and granular activated carbon are primarily used.
Membranes are technically effective, but in municipal wastewater, they usually have a higher cost, greater energy requirements, and a concentrate problem. Therefore, they are more typical for water treatment, water reuse, industrial wastewater, or special applications.
| Technologia | Maturity | Where does it make the most sense? |
|---|---|---|
| Ozonation | high | large municipal wastewater treatment plants, reduction of a wide range of organic compounds |
| Powdered activated carbon | high | wastewater treatment plant modernizations, flexible dosing, variable loads |
| Granular activated carbon | high | final filtration, polishing, stable operation as an adsorption bed |
| Ozone + biological filtration / activated carbon | high / increasing | reduction of by-products and post-ozone polishing |
| Nanofiltration membranes and reverse osmosis | technically mature, but costly | water recovery, drinking water, industry, places with high requirements |
| Advanced oxidation processes | medium / high depending on the system | more difficult compounds, special applications, usually higher cost |
In practice, this means that technologies aimed at micropollutants cease to be a laboratory or pilot solution and become an element of water and wastewater infrastructure. Ozonation and activated carbon are of the greatest implementation importance today, while membranes remain a very effective solution, but more demanding in terms of cost and operation.
Ozonation
Ozonation involves introducing ozone into wastewater after biological treatment. Ozone is a strong oxidant. It reacts directly with some micropollutants or indirectly through reactive oxygen species. It works particularly well on many pharmaceutical compounds, hormones, and organic substances susceptible to oxidation.
| Cecha | Znaczenie |
|---|---|
| Mechanizm | chemical oxidation of micropollutants |
| Strengths | fast action, broad spectrum of compounds, implementation maturity |
| Limitations | possibility of transformation products and oxidation by-products formation |
| Requirements | control of ozone dose, wastewater quality, bromides, nitrites and DOC, i.e. dissolved organic carbon |
| Typical supplement | biological, sand or carbon filtration after ozone |
Ozone does not completely remove the problem in every case. Some compounds are broken down, some are transformed, and transformation products may form in the water. Therefore, in practice, ozonation is often combined with biological post-treatment or activated carbon filtration. The technology is mature but requires control of effluent quality, by-products, and process conditions.
Powdered activated carbon
PAC, or powdered activated carbon, is powdered activated carbon dosed into wastewater as a sorbent. Micropollutants attach to its surface, and then the carbon must be separated from the treated wastewater. It can be used in systems with clarifiers, filtration, or membranes.
| Cecha | Znaczenie |
|---|---|
| Mechanizm | adsorption of micropollutants on a large carbon surface |
| Strengths | flexible dosing, good effectiveness for many organic compounds |
| Limitations | sorbent consumption, need for carbon separation, impact on sludge management |
| Requirements | dosing, mixing, contact, separation, dust and loss control |
| Typical application | wastewater treatment plant modernization without building large granular filters |
PAC is good where flexibility is needed. The dose can be adjusted to the load and the desired effect. The downside is that after use, the sorbent becomes waste or goes for further processing together with the sludge. Therefore, the cost and environmental footprint depend not only on removal efficiency but also on the production, transport, and final disposal of the carbon.
Granular activated carbon
GAC, or granular activated carbon, is granular activated carbon working as a filter bed. Wastewater flows through the filter, and micropollutants are adsorbed on the surface of the grains. Over time, the bed becomes exhausted and requires regeneration or replacement.
| Cecha | Znaczenie |
|---|---|
| Mechanizm | adsorption on a granular activated carbon bed |
| Strengths | stable final filtration, no continuous powder dosing, possibility of post-treatment after ozone |
| Limitations | bed breakthrough and decrease in effectiveness over time |
| Requirements | appropriate pre-filtration, control of DOC, hydraulics, and contact time |
| Typical application | final stage of treatment, often after filtration or ozonation |
GAC works well as an end-of-pipe technology, especially when the treatment plant wants a stable, modular post-treatment stage. Effectiveness depends on the type of compounds, competition with natural organic matter, contact time, and the degree of bed exhaustion. Unlike ozone, activated carbon does not oxidize pollutants; it only adsorbs them. This means the bed needs to be monitored, regenerated, or replaced.
Ozonation combined with activated carbon
Combining technologies is an increasingly practical direction. Ozone breaks down some compounds and improves the biodegradability of some organic matter, while a biological filter or activated carbon further treats the water from transformation products and compounds less susceptible to ozone.
| System | Technological sense |
|---|---|
| Ozone + biological filter | reduction of easily biodegradable products after ozone |
| Ozone + GAC | oxidation and adsorption in a single post-treatment train |
| Ozone + sand filter | basic post-treatment after oxidation |
| PAC + filtration | adsorption with sorbent separation |
| PAC + ultrafiltration | effective carbon separation, but greater installation complexity |
Technology combinations are particularly important because micropollutants are not a single substance. Some compounds react better with ozone, while others adsorb better on carbon. Therefore, hybrid systems are more resistant to variations in wastewater composition. In practice, this means greater process stability, but also more complex operation.
Membranes
Membranes are technically mature, but their place in micropollutant removal needs to be described carefully. Microfiltration and ultrafiltration effectively remove suspended solids, bacteria, and some microplastics, but they do not effectively retain many dissolved organic micropollutants. Nanofiltration or reverse osmosis is usually needed to remove small molecules.
| Membrane technology | What it removes | Limitation |
|---|---|---|
| Microfiltration | suspended solids, some microorganisms, larger particles | poor for dissolved micropollutants |
| Ultrafiltration | suspended solids, colloids, microorganisms, some microplastics | usually requires combination with PAC or another process for micropollutants |
| Nanofiltration | many organic compounds and multivalent ions | cost, fouling, concentrate |
| Reverse osmosis | very broad removal of dissolved substances | high energy consumption and brine / concentrate problem |
| Membrane bioreactor | better biomass separation and effluent quality | does not remove all micropollutants by itself |
Membranes are very effective where a high level of purification or water reuse is needed. In classic municipal wastewater treatment plants, their limitations are energy cost, susceptibility to fouling, i.e., membrane clogging, and the need to manage the concentrate. Therefore, for large municipal wastewater, ozone and activated carbon are usually more typical fourth-stage technologies than full reverse osmosis.
Which pollutants are removed by which technology?
There is no single technology that removes everything equally well. The selection depends on the pollutant profile, wastewater matrix, legal requirements, cost, available space, and the risk of by-products.
| Pollutant group | Technologies usually effective | Notes |
|---|---|---|
| Oxidation-susceptible drugs and hormones | ozonation, ozone + filtration | good effectiveness, but control of transformation products |
| Hydrophobic compounds | PAC, GAC | good adsorption on activated carbon |
| Polar and persistent compounds | nanofiltration, reverse osmosis, selected AOPs, i.e., Advanced Oxidation Processes | more difficult and expensive removal |
| Pesticides | ozone, activated carbon, membranes depending on the compound | effectiveness dependent on substance chemistry |
| PFAS, i.e., per- and polyfluoroalkyl substances | GAC, ion exchange resins, nanofiltration, reverse osmosis | ozone is usually not sufficient for persistent PFAS |
| Mikroplastik | filtration, ultrafiltration, membranes, mechanical processes | a different problem than dissolved micropollutants |
| Transformation products | biological filtration, GAC, monitoring | may form after ozone |
The most important conclusion: technology should be selected based on the list of target substances. A system is designed differently for drug residues, differently for PFAS, and differently for microplastics. There is no single universal device that removes all micropollutants with the same effectiveness and cost.
Technological maturity in practice
The most practical criterion for maturity is the number of full-scale installations, the possibility of process design, supplier availability, known risks, and the possibility of operation by a typical wastewater treatment plant.
| Technologia | Maturity assessment | Komentarz |
|---|---|---|
| Ozonation | mature | full-scale technology, good for many organic micropollutants |
| PAC | mature | flexible, but generates spent sorbent and requires separation |
| GAC | mature | good as a final filter, requires breakthrough control and regeneration |
| Ozone + GAC / biofilter | mature / very promising | combines oxidation with post-treatment |
| Nanofiltration | technically mature | limited in municipal wastewater by cost and concentrate |
| Reverse osmosis | very technically effective | rather for reuse, industry and high requirements than as a municipal standard |
| AOP | system-dependent | effective, but often more expensive and more energy-intensive |
| Biological solutions in themselves | insufficient as the sole fourth stage | can support advanced treatment, but are not universal |
Technology maturity does not mean it can be copied one-to-one between treatment plants. Wastewater composition, industrial share, DOC, bromides, suspended solids, flows, recipient requirements, and energy costs can significantly alter the choice of the best system.
Risks and limitations
Mature technology does not mean trouble-free technology. Each of the main methods has its limitations. The most important thing is not only the removal of indicator substances but also the control of process side effects.
| Technologia | Main risk | What needs to be controlled |
|---|---|---|
| Ozonation | transformation products, bromates, effluent toxicity | bromides, ozone dose, DOC, ecotoxicological tests, advanced treatment |
| PAC | spent carbon and sludge management | dose, separation, impact on sludge, sorbent cost |
| GAC | bed breakthrough and decrease in efficiency | monitoring of indicator substances, regeneration, bed replacement |
| Membranes | fouling, energy, concentrate | pretreatment, cleaning, water recovery, concentrate management |
| AOP | cost of energy and reagents | dose, effectiveness, by-products |
| Hybrid systems | operational complexity | automation, monitoring, operator competence |
The most critical aspects are ozonation in wastewater with a high potential for by-product formation, and membranes, which transfer the problem to the concentrate. Activated carbon, on the other hand, does not destroy pollutants; it only transfers them to a sorbent that needs to be managed.
How to choose?
Technology selection should start with the pollutant profile and treatment goal, not equipment preference. A different system will be optimal for a large municipal wastewater treatment plant, another for a hospital, pharmaceutical industry, cosmetic plant, water intake, or a reuse installation, i.e., water reuse.
| Design question | Znaczenie |
|---|---|
| What substances are a problem | determines whether ozone, carbon, membrane, or a hybrid system will be better |
| Is removal or transformation required | ozone oxidizes, carbon adsorbs, membrane separates |
| What is the water / wastewater matrix | DOC, suspended solids, bromides, nitrites, and salinity affect the process |
| Is there a PFAS problem | standard ozonation is not the main answer |
| Is the water to be reused | then membranes and multi-barrier systems gain importance |
| What are the costs of energy and reagents | impact on OPEX, i.e., operating costs |
| What to do with sludge, spent carbon, or concentrate | without this, the process is not closed |
| How to monitor effectiveness | indicator substances and effluent monitoring are needed |
The safest selection logic is as follows: for typical organic micropollutants in municipal wastewater, ozonation, PAC, or GAC are considered first. For more difficult, persistent, and very polar compounds, membranes, resins, AOPs, or multi-stage systems need to be analyzed.
Micropollutant removal is no longer solely a laboratory topic. Ozonation and activated carbon are mature technologies, applied at full scale and ready for implementation as a fourth treatment stage. Membranes are technically very effective, but in municipal wastewater, their application is limited by costs, energy, and concentrate.
The shortest message is simple: mature micropollutant removal today relies mainly on ozone and activated carbon, while membranes are a tool for situations requiring a very high separation barrier.
In practice, the best results are achieved not by a single device, but by a well-selected technological sequence, monitoring of indicator substances, and control of by-products.
Źródła
- Kompetenzzentrum Wasser Berlin — 4th Treatment Stage / fourth treatment stage
https://kompetenz-wasser.de/en/forschung/dienstleistungen/4-reinigungsstufe - Micropoll Switzerland — knowledge platform on micropollutants and treatment technologies
https://micropoll.ch/en/home/ - Water Research — Full-scale ozonation for micropollutant removal in wastewater treatment
https://www.sciencedirect.com/science/article/abs/pii/S0043135417308734 - Science of the Total Environment — Granular activated carbon and powdered activated carbon for micropollutant removal
https://www.sciencedirect.com/science/article/pii/S0048969721073010 - Environments 2024 — Technologies for micropollutant removal in wastewater treatment plants
https://www.mdpi.com/2076-3298/11/11/241 - European Commission — Urban Wastewater Treatment Directive, revised rules including micropollutants
https://environment.ec.europa.eu/topics/water/urban-wastewater_en - European Parliament — Urban wastewater treatment: revised rules
https://www.europarl.europa.eu/thinktank/en/document/EPRS_BRI(2022)698881 - German Environment Agency — Advanced wastewater treatment and micropollutants
https://www.umweltbundesamt.de/en/topics/water/wastewater/advanced-wastewater-treatment - Swiss Federal Office for the Environment — Micropollutants in wastewater
https://www.bafu.admin.ch/bafu/en/home/topics/water/info-specialists/measures-for-water-protection/wastewater-treatment/micropollutants-in-wastewater.html - Review — Ozonation and activated carbon for the removal of organic micropollutants
https://www.sciencedirect.com/science/article/pii/S0043135421009774 - Review — Membrane processes for micropollutant removal and water reuse
https://www.sciencedirect.com/science/article/pii/S0011916421000120 - Review — Advanced oxidation processes for micropollutant removal
https://www.sciencedirect.com/science/article/pii/S138589471931707X